10base-T, 100base-TX/T4, 1000base-T
There is NOTHING more annoying than spending 30 minutes debugging a
network problem to find it was the cable. Badly made or non-standard cabling is
a foolish thing to spend time on - do it once and do it right. This guide may
help you to forget cabling problems and spend time time doing really useful
things - like pondering the meaning of life.
Contents
Crossed and Straight cables - when to use
them.
Standards Summary
Category 5 (UTP) colour coding table
10base Straight Cable (PC to HUB/SWITCH)
10baseT Crossed cable (PC to PC or HUB to HUB)
100baseT Straight Cable (PC to HUB/SWITCH)
100baseT Crossed cable (PC to PC or HUB to HUB)
1000base-T Gigabit Ethernet
RJ45 Connector Pin Numbering
RJ45 Connections - some hints
Shielded Twisted Pair (STP)
Notes:
- LAN cables are generically called UTP (Unshielded Twisted Pair) and are
identified with a category rating. When installing new cable, unless there is
a very good reason not to, you should be using category 5, 5e or 6 UTP which
is rated for both 10 and 100mb LAN operation. Info
on Shielded Twisted Pair (STP) cabling.
- UTP comes in two forms SOLID or STRANDED. SOLID refers to
the fact that each internal conductor is made up of a single (solid!) wire,
STRANDED means that each conductor is made up of multiple smaller wires.
Stranded cable (which is typically more expensive) has a smaller 'bend-
radius' (you can squeeze the cable round tighter corners with lower loss) and
due to its flexibility should be used where you plug and unplug the cable
frequently. All other things being equal the performance of both types of
cable is the same. In general, solid cable is used for backbone wiring and
stranded for PC to wall plug (patch) cables. Beware: Each type of wire,
solid or stranded, needs its own connector type.
- <rant> There is NO excuse with all the choice of color cable and
other techniques available to-day for not being able to visually spot the
difference between at least a straight and a crossed cable
before you spend 1 hour fitting the wrong cable into your network. For
cheap-skates (which includes us) you can get heat-shrink colour tubing in a
slew of colours which you fit on each end of the cable beside the connector to
indicate the wiring type and standard instead of using different coloured
cables. The advantage of this scheme is that when you change your wiring
standard you can just change the sleeve colour - you don't have to rip out the
cable. Disadvantage: You have to remember to put the tubing on BEFORE
the connector! </rant>
- You CAN use 100base-TX wiring with a 10base-T network (but not always the
other way round). In general ALWAYS use 100baseTX/T4 wiring standards.
- If you are using category 5, 5e or 6 wiring EVERYWHERE you can use the
100base-TX standard (this only uses 2 pairs , 4 conductors). Most of the
information below assumes you are using category 5, 5e or 6 cables.
- If you are using category 3 or 4 cables with 100M LANs ANYWHERE you MUST
use the 100Base-T4 standard and this has ADDITIONAL RESTRICTIONS documented
throughout (it uses all 4 pairs, 8 conductors). LAN connections/pinouts are
defined by IEEE
802.3u.
- Maximum LAN cable runs are 100 meters (~300ft).
- We provide a
Cabling FAQ which provides additional information or background.
- We have added an article on
mixing 100 MB LAN and Telephony on a single category 5(e) or 6 cable. It
can be done, but you must be very, very cautious.
- We have updated some of the material for 1000base-T (Gigabit Ethernet
802.3ab) which uses all 4 pairs (8 conductors) and added notes where relevant
about Power-over-Ethernet (PoE 802.3af). A copper standard for 10GB Ethernet
is being worked on (802.3an) but as of February 2005 the IEEE was still
standardizing away.
The following diagram shows the Normal use of Crossed and Straight
cables (see also the notes below).

Notes:
- We show Straight cables as BLUE and
Crossed as RED. That is our convention.
The cable color can be anything you choose or, more likely, the vendor
decides.
- To avoid the need for Crossed cables many vendors provide UPLINK
ports on Hubs or Switches - these are specially designed to allow the use of a
STRAIGHT cable when connecting back-to-back Hubs or Switches. Read the
manufacturers documentation carefully.
- Increasingly vendor hubs (can you still buy them) and switches will
auto-detect the connection type and internally switch the connectors so that
STRAIGHT cables can be used everywhere.

The various standards can get a tad complicated and messy. We get occasional
email requesting a summary of the standards - this is our attempt to provide a
quick overview.
| Standard |
Required Pairs |
10M |
100M |
1000M |
Notes |
| 10base-T |
2 (1/2 and 3/6) |
yes |
yes |
no |
100m support only if no cat 3/4 in run |
| 100base-TX |
2 (1/2 and 3/6) |
yes |
yes |
no |
100m support only if no cat 3/4 in run |
| 100base-T4 |
4 (1/2, 3/6, 4/5 and 7/8) |
yes |
yes |
yes |
|
| 1000base-T |
4 (1/2, 3/6, 4/5 and 7/8) |
yes |
yes |
yes |
Functionally identical to 100base-T4 |

The following table shows the normal colour coding for category 5 cables (4
pair) based on the two standards supported by TIA/EIA (see also our
primer on this topic)
We get occasional email about the difference between 568A and 568B wiring.
Which one you use is a matter of local decision. These standards apply to the
color code used within any SINGLE cable run - BOTH ENDS MUST USE THE SAME
STANDARD. However, since they both use the same pinout at the connectors you can
mix 568A and 568B cables in any installation.


Straight cables are used to connect PCs or other equipment to a HUB or
Switch. If your connection is PC to PC or HUB to HUB you MUST use a
Crossed cable.
The following cable description is for the wiring of both ends (RJ45 Male
connectors) with the 568B category 5(e) wiring
colors you could, of course, use the 568A colour scheme.
| Pin No. |
strand color |
Name |
| 1 |
white and orange |
TX+ |
| 2 |
orange |
TX- |
| 3 |
white and green |
RX+ |
| 4 |
NC |
* |
| 5 |
NC |
* |
| 6 |
green |
RX- |
| 7 |
NC |
* |
| 8 |
NC |
* |
NOTE: Items marked * are not necessary for 10M LANs (10base-T) but
since you will be moving shortly to 100MB LANs (won't you) you will save
yourself a LOT OF TIME finding crappy cable (that you made) that does not
work. Instead we suggest you wire to 100Base-T4
standards. After all you gotta stick the ends somewhere man.
We use BLUE for 10base-T straight cables.
NOTE: All our wiring is now done to the 100base-T4 spec which you can use with
10base-T networks - but NOT necessarily the other way around.

Crossed cables are used to connect PCs to one other PC or to connect a HUB to
a HUB. Crossed cables are sometimes called Crossover, Patch or Jumper cables. If
your connection is PC to HUB you MUST use a Straight
cable.
The following description shows the wiring at both ends (male RJ45
connectors) of the crossed cable.
One end
RJ45 Male |
Other end
RJ45 Male |
| 1 |
3 |
| 2 |
6 |
| 3 |
1 |
| 4 * |
5 * |
| 5 * |
4 * |
| 6 |
2 |
| 7 * |
8 * |
| 8 * |
7 * |
NOTES:
- Items marked * are not necessary for 10M LANs but since you will be moving
shortly to 100MB LANs (won't you) you will save yourself a LOT OF TIME
finding crappy cable (that you made) that does not work. Instead we suggest
you wire to 100BaseT standards.
- We use RED for crossed cables (or more
commonly now a red heat-shrink collar at each end).
- All our crossed wiring is done to the 100base-T4 spec which you can use
with 10baseT networks - but NOT always the other way around.

Straight cables are used to connect PCs or other equipment to a HUB or
Switch. If your connection is PC to PC or HUB to HUB you MUST use a
Crossed cable.
The following cable description is for the wiring of BOTH ends (RJ45 Male
connectors) with your category 5 wiring colors
(TIA/EIA 568A or 568B though the example uses 568B colors).
| Pin No. |
conductor color |
Name |
| 1 |
white and orange |
TX_D1+ |
| 2 |
orange |
TX_D1- |
| 3 |
white and green |
RX_D2+ |
| 4 |
blue |
BI_D3+ ** |
| 5 |
white and blue |
BI_D3- ** |
| 6 |
green |
RX_D2- |
| 7 |
white and brown |
BI_D4+ ** |
| 8 |
brown |
BI_D4- ** |
We use BLUE for 100baseT straight cables.
NOTES:
- Wires marked ** are ABSOLUTELY NECESSARY for 100Base-T4 networks - used
when any combination of category 3/4/5 cables are present, when using
1000base-T (GigE) and MAY be required for Power-over-Ethernet (PoE) - see
below.
- Wires marked ** are not essential for 100Base-TX (using cat 5/5e ONLY
cables) and CAN be used for other purposes, for example, telephony but,
.. beware .. read this FAQ and our
LAN plus Telephony article before you wire your entire neighbourhood for
surround sound.
- The Power-over-Ethernet spec (802.3af) allows three schemes where power
may be supplied. Two of these schemes use pairs 4,5 and 7,8 (marked ** in
above table) for power (called Midspan PSE and Alternative B or Mode B), one
scheme uses ONLY pairs 1,2 and 3,6 (Endpoint PSE, Alternative A or Mode A) for
both signals and power. Depending on which scheme you use pairs 4,5 and 7,8
may be required.
- Gigabit Ethernet requires all 4 pairs (8
conductors).
- All our wiring is now done to the 100base-T4 spec which you can use with
10baseT networks - but NOT the other way around.

Crossed cables are used to connect PCs to one other PC or to connect a HUB to
a HUB. Crossed cable are sometimes called Crossover, Patch or Jumper cables. If
your connection is PC to HUB you MUST use a
Straight cable.
The following description shows the wiring at both ends (male RJ45
connectors) of the crossed cable. Note: The diagrams below shows crossing
of all 4 pairs and allows for the use of cat3/4 cables with 100m LANs
(100base-T4). Pairs 4,5 and 7,8 do not NEED to be crossed in 100base-TX wiring.
See notes below.

We use RED for crossed cables (or more
commonly now a red heat-shrink collar at each end).
NOTES:
- All our crossed wiring is now done to the 100base-T4 spec (uses all 4
pairs, 8 conductors) which you can use with 10base-T networks - but NOT
necessarily the other way around.
- Many commercial 100m LAN cables seem not to cross pairs 4,5 and 7,8. If
there is no cat3/4 wiring in the network this perfectly acceptable.
- Gigabit Ethernet uses all 4 pairs so requires the full 4 pair (8
conductor) cross configuration (shown above).
- If you are using Power-over-Ethernet (802.3af) then Mode A or Alternative
A uses pairs 1,2 and 3,6 for both signals and power. Mode B or alternative B
uses 4,5 and 7,8 to carry power. In all cases the spec calls for polarity
insensitive implementation (using a diode bridge) and therefore crossing or
not crossing pairs 4,5 and 7,8 will have no effect.

1000base-T is the copper based version of the gigabit Ethernet standard
defined by 802.3ab which, since it is over 6 months old, is available free of
charge from the enlightened IEEE. Great work. In passing, if you want to see
sophistry raised to an art form read the EIA's justification for charging for
their specifications. (Note: The original EIA statement is unfortunately
no longer avilable on-line. This is a great loss to both the development of the
English language in general, and comedy writing in particular.) The following
notes apply to the 1000base-T spec:
- The standard defines auto-negotiation of speed between 10, 100 and 1000
Mbit/s so the speed will fall to the maximum supported by both ends - ensuring
inter-working with existing installations.
- The cable specification base-line is ANSI/TIA/EIA-568-A-1995 (which you
have to pay for). This means that if you know your cat5 cable was
manufactured to this standard (there was a lower spec 1991 version of this
specification) then it will support Gigabit Ethernet. Cat5 cable manufactured
to the old specification may work or it may not - you need to run some tests.
Cat5e and cat6 being higher spec cables will clearly support Gigabit Ethernet.
- Maximum runs are the standard 100m (~300ft).
- Gigabit Ethernet uses all 4 pairs (8 conductors). The transmission scheme
is radically different (PAM-5 a 5 level amplitude modulation scheme) and each
conductor is used for send and receive.
- Crossed Gigabit Ethernet cables must cross
all 4 pairs.

RJ45 Male Connector


We get mail saying 'Help. I've wired it correctly but it does not work'. Here
are some simple notes that may help. Remember: it's more difficult that you
think.
- The RJ45 connector is the critical connection - always use the highest
quality connectors you can afford. The most common cause of connection faults
are bad connectors.
There are different connectors for stranded and solid cable
and manufacturers do not always do a good job at differentiating them. Spend
the time to make sure you have the right connector type. If you use the
wrong type of connector the cable may work initially but it will almost
certainly fail very quickly.
- Make and test practice cables until you get it right every time -
especially before you destroy a cable you just spent 2 hours fitting.
- When cutting the exterior cover of the cable be very careful not to cut
the insulation cover of the conductors since this can cause shorts. Bottom
line: the cable won't work.
- Expose a maximum of 1 inch of individual conductors when preparing the
cable for connection.
- Line up all the conductors according to the wiring standard you are using.
- Measure the cable end by placing it beside the RJ45 and trim the conductor
ends so they are are all the same length and no individual conductor wire is
visible outside the plastic cover of the RJ45 connector.
- Carefully slide the prepared cable into the RJ45 connector making sure the
end of the conductors reaches the end of the RJ45 connector.
- Using the crimp tool make the connection with a single firm squeeze
operation.
- Test the cable before fitting if possible.

Shielded Twisted Pair (STP) comes in a variety of formats. It is typically
used in three applications:
- Where there is significant EMI (Electro-Magnetic Induction) in the
environment such as caused by high-powered electric motors (such as in
elevator shafts), flourescent lighting etc. Additionally where there is
significant Alien Crosstalk (ANEXT) such as in very high speed (gigabit and
10gb) LANs. In this case the ethernet signals in the cable require protection
against external interference from either adjacent pairs or the environment.
- Where there is extremely sensitive electrical/electronic equipment in the
surrounding environment or where security requirements demand elimination of
eavesdropping possibilities from radiated LAN signals (TEMPEST). In this case
the ethernet signals in the shielded cable are contained and prevented from
polluting, or escaping into, the external environment.
- Where maximum performance - either speed or distance - is required. As
Ethernet speeds continue to increase either fiber or Shielded Twisted Pair is
becoming increasingly common, for instance, to reach 100m distances at 10Gb
speeds on copper will require shielded cable (limited to 55m for UTP).
Shielded cable comes in three broad types with a confusing range of
terminology:
- Where there is a single foil (FTP - Foil Twisted Pair) or braided (ScTP -
Screened Twisted Pair) shield inside the jacket covering all four pairs.
Suitable for applications 1 and 2 above.
- Where there is a foil shield covering each pair. This is frequently
refered to as PiMF (Pairs in Metal Foil) and is designed primarily to
eliminate Alien Cross-talk (ANEXT) from adjacent pairs. Suitable for
application 3 above.
- Where there is a foil shield covering each pair and a (Foil or Braided)
shield covering the whole cable. This is frequently refered to as SSTP (Double
Shield Twisted Pair) or even PiMF - since many manufacturers also add a jacket
shield to foil covered pair cables. Suitable for applications 1, 2 and 3
above.
In almost all cases there is a single ground wire (called a drain) which
allows for connection to secondary grounding sources.
The diagram below illustrates the differences:

Notes:
- Shielded cable of any variety has a greater diameter than UTP and will
therefore occupy more space in cable ducting and raceways.
- Connecting shielded cable is more complex and time consuming - but not
execessively so - than conventional UTP. Manufacturers specifications vary
enormously, expecially with respect to grounding, and should be followed
closely.
- In shielded cable installations the jacks and receptacles are typically
made of metal and the cable shield (foil or braid) is connected electrically
to the connector and thence through the metal receptable to a suitable ground
provided by the end equipment.
- Foil covered pairs are typically not connected to ground and thus provide
only alien crosstalk immunity from adjacent pairs (ANEXT).
- Manufacturers specifications and measurements suggest that shielded cables
do NOT create antenna effects - indeed experiments show that UTP creates a
substantially greater antenna effect (~40db) over correctly grounded shielded
cables.
- Even ungrounded shielded cables provide better performance (by ~20db) than
conventional unshielded twisted pair (UTP).
- The drain wire provides a secondary or auxiliary ground method in cases
where metallic path grounding is provided by the connectors and, as such, is
optional. In cases where metal connectors are not being used (there is no
grounding via the connectors) the drain wire may be used as the primary
grounding method and needs to be routed independantly to a suitable ground.
The drain wire (cable ground) needs to be exposed before connector. This
process could require a considerable length of exposed drain wire depending on
the location of the ground source. A plastic insulating sheath should be
placed over the drain wire to minimize electrical hazards.